TM 10-4610-239-24
TM 08580B-24/3
REMOVAL. (Cont)
e. Remove vent vessels gate valve (10) with adapter (11) and pipe section (12) from control panel (13).
f.
Remove adapter (11) and pipe section (12) from vent vessels gate valve (10).
g. Remove ring filler (14) and Nomex tape (15) from pipe section (12).
INSTALLATION.
NOTE
Apply antiseize tape to all male pipe threads before installation.
a. Wrap pipe section (12) with Nomex tape (15) where two-pece strap (5) will be positioned.
i
b. Install ring filler (14).
c.
Install adapter (11) and pipe section (12) on vent vessels gate valve (10).
d. Position pipe section (12) through cutout on control panel (13).
e. Install gasket (9), clamp (8), two screws (7), and nuts (6).
CAUTION
Pipe section can be badly damaged by corrosion if it contacts
strap. Be sure to separate pipe section from strap with Nomex
tape.
f.
Position two-piece strap (5) on ring filler (14) and nuts (4).
g. Install two screws (3) and nuts (2).
h. Tighten two nuts (4) and (2) and install cap (1).
2-231