TM 10-4610-239-24
TM 08580B-24/3
2-97. REPLACE RAW WATER FLOWMETER.
This task covers: a. Removal. b. Installation.
INITIAL SETUP.
a. Tools.
Tool Kit (Appx B, Sect III, Item 10).
b. Materials/Parts.
Antiseize Tape (Appx C, Sect II, Item 17).
c.
Equipment Condition. Power shut down (power source manual). ROWPU shut down (TM 10-4610-239-10).
REMOVAL.
a. Remove two nuts (5), bolts (6), clamp (7), and gasket (8).
b. Remove two nuts (10), bolts (11), clamp (12), and gasket (13).
2-234