TM 10-4610-239-24
TM 08580B-24/3
REMOVAL. (Cont)
b. Remove two nuts (2), lockwashers (3), flat washers (4), and screw (5). Discard lockwashers.
c.
Loosen two nuts (6) and remove two-piece strap (7).
NOTE
Tag ends of pressure tubes before removal.
d. Disconnect two pressure tubes (8) from adapters (9) and (12) at filter gage (14).
e. Remove two nuts (18), lockwashers (19), and bracket (20) from studs (21). Discard lockwashers.
f.
Remove two nuts (22), screws (23), clamp (24), and gasket (25).
g. Tilt pipe section (26) and pipe assembly (27) and remove from control panel (28) with flowmeter (29).
h. Remove pipe section (26) and pipe assembly (27) from flowmeter (29).
i.
Remove ring filler (30) and Nomex tape (31) from pipe assembly (27).
INSTALLATION.
NOTE
Apply antiseize tape to all male pipe threads before installation.
a. Install pipe section (26) and pipe assembly (27) on flowmeter (29).
b. Position flowmeter (29) face in cutout on control panel (28). End of pipe asse bly (27) must protrude
m
through control panel cutout.
c.
Position bracket (20) on two studs (21) and install two new lockwashers (19) and nuts (18).
d. Install gasket (25), clamp (24), two screws (23), and nuts (22).
e. Install pressure tubes (8) on adapters (9) and (12) at tee connection (13) and elbow (10).
2-237