TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
a.
Unscrew three connectors (1) and remove four-way distribution block (2).
b.
Remove two nuts (3), lockwashers (4), and bracket (5). Discard lockwashers.
c.
Remove R.O. pressure gage (6) from front of control panel (7).
INSTALLATION.
NOTE
Apply antiseize tape to all male pipe threads before installation.
a. Position R.O. pressure gage (6) in cutout on control panel (7).
b. Position mounting bracket (5) on rear of control panel (7) and install two new lockwashers (4) and nuts (3).
c.
Install four-way distribution block (2) and three connectors (1).
2-256