TM 10-4610-239-24
TM 08580B-24/3
2-107. REPLACE DRAIN BALL VALVE.
This task covers:
a.
Removal.
b.
Installation.
INITIAL SETUP.
a.
Tools.
Tool Kit (Appx B, Sect III, Item 10).
b.
Materials/Parts.
Antiseize Tape (Appx C, Sect II, Item 17).
c.
Equipment Condition.
Power shut down (power source manual).
ROWPU shut down (TM 10-4610-239-10).
REMOVAL.
NOTE
There are seven drain ball valves. All are removed the same. One is shown.
a.
Remove tube (1) from adapter (2).
2-260