TM 10-4610-239-24
TM 08580B-24/3
REMOVAL. (Cont)
b.
Remove nut (3) and handle (4).
NOTE
Label drain ball valve before removal. Valves must be installed in same location from
which removed.
c.
Support drain ball valve (5) and remove two screws (6) and lockwashers (7). Discard lockwashers.
d.
Lower drain ball valve (5) and tilt to remove from hole in bracket (8).
e.
Remove adapter (2) from drain ball valve (5).
INSTALLATION.
NOTE
There are seven drain ball valves. All are installed the same. One is shown.
Install drain ball valve in position labeled.
Apply antiseize tape to male pipe threads before installation.
a.
Install adapter (2) on drain ball valve (5).
b.
Position drain ball valve (5) on bracket (8) and install two new lockwashers (7) and screws (6) fingertight.
c.
Install handle (4) and nut (3).
d.
Install tube (1) on adapter (2).
e.
Tighten two screws (6).