REMOVAL.
a.
Loosen setscrew (1) and remove handle (2) from three-way ball valve (3).
NOTE
Tag flexible tubing before disconnecting.
b.
Disconnect three clamps (4) and remove flexible tubing (5).
c.
Remove locknut (6) and three-way ball valve from mounting plate (7).
d.
Remove two elbows (8) and adapter (9) and retain for reinstallation.
INSTALLATION
NOTE
Apply antiseize tape to pipe fittings before installation.
a.
Install two elbows (8) and adapter (9).
b.
Position three-way ball valve (3) on mounting plate (7) and install locknut (6), handle (2), and tighten setscrew (1).
c.
Place three clamps (4) on flexible tubing (5) and install on two elbows (8) and adapter (9). Tighten clamps.
2-283