TM 10-4610-239-24
TM 08580B-24/3
REMOVAL. (Cont)
b.
Loosen nut (2) and remove flexible shaft (3) from adjusting spindle (4).
c.
Remove adjusting spindle (4) and O-ring (5) from metering and drive assembly (6). Discard O-ring.
d.
Loosen grub screw (7) and remove flexible shaft (3).
e.
Remove three screws (8) and remove stroke adjustment head (1) from mounting plate (9).
INSTALLATION.
NOTE
There are four manual stroke adjustment assemblies. All are installed the same. One is
shown.
a.
Position stroke adjustment head (1) on mounting plate (9) and install three screws (8).
b.
Position flexible shaft (3) on stroke adjustment head (1) and tighten grub screw (7).
c.
Install new O-ring (5) and adjusting spindle (4) in metering and drive assembly (6).
d.
Install flexible shaft (3) in adjusting spindle (4) and tighten nut (2).
2-279