TM 10-4610-239-24
TM 08580B-24/3
2-126. REPLACE R.O. PUMP OIL VALVE AND AIR BREATHER.
This task covers:
a. Removal.
b. Installation.
INITIAL SETUP.
a.
Tools. Tool Kit (Appx B, Sect III, Item 10).
b.
Materials/Parts.
Oil, Lubricating (Appx C, Sect II, Item 11).
Antiseize Tape (Appx C, Sect II, Item 17).
c.
Equipment Condition.
Power shut down (power source manual).
ROWPU shut down (TM10-4610-239-10).
Oil drained from R.O. pump assembly (LO 10-4610-239-12).
REMOVAL.
a.
Loosen clamp (1) and remove drain hose (2) from adapter elbow (3).
b.
Remove adapter elbow (3) from oil drain valve (4).
c.
Remove nut (5), washer (6), and handle (7).
2-306