TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
a.
Remove five screws (1), lockwashers (2), and clamps (3) securing water hose (4) and oil hose (5)
to pump and motor stand (6). Discard lockwashers.
b.
Remove water hose (4) and oil hose (5) from pump and motor stand (6).
c.
Remove 10 screws (7) and lockwashers (8) securing pump and motor stand (6) to ROWPU
frame. Discard lockwashers.
WARNING
The R.O. pump, motor stand, and mounting plate are heavy. Two people
are needed to lift them to prevent personal injury or damage to the
equipment.
d.
Remove pump and motor stand (6) from ROWPU.
e.
Remove two grooved pins (9) and flat washers (10) from adjusting bolt (11).
f.
Remove adjusting bolt (11) and stop nut (12).
g.
Remove four nuts (13), lockwashers (14), flat washers (15), and screws (16) from mounting plate
(17). Discard lockwashers.
h.
Remove R.O. pump electric motor mounting plate (17).
i.
Remove two rubber grommets (18) from R.O. pump and motor stand (6).
INSTALLATION.
WARNING
The R.O. pump, motor stand, and mounting plate are heavy. Two people
are needed to lift them to prevent personal injury or damage to the
equipment.
a.
Position R.O. pump electric motor mounting plate (17) on pump and motor stand (6) and install
four screws (16), flat washers(15), new lockwashers (14), and nuts (13).
b.
Install stop nut (12), adjusting bolt (11), washer (10), and pins (9).
c.
Install two flat washers (10) and grooved pins (9) on adjusting screw (11).
d.
Position pump and motor stand (6) on ROWPU and align mounting holes.
e.
2-313