Table 3-1. Direct Support Troubleshooting - Continued
Malfunction
Test or Inspection
Corrective Action
BOOSTER PUMP ASSEMBLY - Continued
PUMP ELECTRIC MOTOR FAILS TO START WHEN BOOSTER PUMP SWITCH IS SET TO START - Continued
Step 7.
Shut down ROWPU. Refer to TM 10-4610-239-10. Shut down power. Refer to
generator manual. Refer to schematic diagram figure FO-3. Check for short
circuits between junction box ground terminal El and K6 terminals T1, T2, and
T3.
If any terminal is shorted to ground terminal E1, go to step 8.
If no terminal is shorted to ground terminal E1 replace K2. Refer to
Step 8.
schematic diagram figure FO-3. Check for short circuits between wire lugs on
motor cable.
If any lugs are shorted, repair booster pump cable assembly. Refer to
If no lugs are shorted, repair booster pump electric motor. Refer to
Step 9.
Shut down ROWPU. Refer to TM 10-4610-239-10. Shut down power. Refer to
generator manual. Remove booster pump cable assembly from motor. Refer to
paragraph 3-31. Leave cable connected to
K6. Refer to
schematic diagram figure
FO-3. Check continuity between K6
terminals T1, T2, and 13
and wire lugs on
end of cable.
If any measurement does not indicate continuity, repair booster pump
If all three measurements indicate continuity, repair booster pump
Step 10.
Shut down ROWPU. Refer to TM 10-4610-239-10. Shut down power. Refer to
generator manual. Refer to interconnect diagram figure FO-4. Check for
continuity between K6 terminals L1, L2, and L3 and J1 pins A, B, and C
respectively.
If all three measurements do not indicate continuity,, go to step 11.
If all three measurements indicate continuity, repair K6. Refer to