REMOVAL.
WARNING
High voltages in this equipment can cause serious injury or death. Be certain
that all power is removed before performing maintenance.
a. Remove 14 screws (1), flat washers (3), lockwashers (2), and control box cover (4).
b. Remove cable connector (5) from receptacle connector (6).
NOTE
There are two electrical cables installed on terminals in the control box
assembly. Both are removed the same.
Tag wires before removal.
c.
Remove three screws (7) and wires (8).
d. Remove locknut (9) from cable grip (10) and remove electrical cable (11). Retain locknut.
e. Repeat steps c and d for electrical cable (12).
f.
Support control box assembly (13) and remove four nuts (14), lockwashers (15), flat washers (16), and
screws (17). Discard lockwashers.
g. Remove control box assembly (13).
h. Close control box cover (4) and install but do not tighten 14 screws (1), lockwashers (2), and flat
washers (3).
INSTALLATION.
WARNING
High voltages in this equipment can cause serious injury or death. Be certain
that all power is removed before performing maintenance.
The control box assembly is heavy/difficult to handle. Two people are needed
to lift it to prevent personal injury or damage to the equipment.
a. Remove 14 screws (1), lockwashers (2), and flat washers (3). Lower control box cover (4). Discard
lockwashers.
WARNING
The control box assembly is heavy/difficult to handle. Two people are needed
to lift it to prevent personal injury or damage to the equipment.
b. Support control box assembly (13) and install four screws (17), flat washers (16), new lockwashers (15),
and nuts (14).
c.
Install cable connector (5) on receptacle connector (6).
3-162