TM 10-4610-239-24
TM 08580B-24/3
WARNING
High voltages in this equipment can cause serious injury or death. Be certain
that all power is removed before performing maintenance.
NOTE
There are two control relays in the electrical junction box assembly. Both are
removed and installed the same. One is shown. K-8 relay has eight wires and
K-9 relay has seven wires.
REMOVAL.
a. Turn 13 rotary fasteners (1) and lower junction box cover (2).
NOTE
Tag all wires before removal.
b. Remove six screws (3) and eight terminal lugs (4) from control relay (5).
c.
Loosen two screws (6) and lift up and remove control relay (5).
INSTALLATION.
a. Position control relay (5) and tighten two screws (6).
b. Position eight wires (4) as tagged and install six screws (3).
c.
Close junction box cover (2) and turn 13 rotary fastenes (1).
r
3-192