TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
a.
Remove four screws (1) and conduit box cover (2) from conduit box (3).
NOTE
Tag all wires before removal.
b.
Pull two wire bundles (4) out of conduit box (3) far enough to expose taped ends. Remove twine (5) from both
bundles.
c.
Remove electrical tape (6) from two wire bundles (4) and tag motor wires with color of power source wire in each
bundle.
d.
Remove nut (7), lockwasher (8), four wire lugs (9) and (10), and flat washer (11) from screw (12) on each wire
bundle (4).
e.
Install flat washer (11), three wire lugs (10) from motor, lockwasher (8), and nut (7) on screw (12) on each wire
bundle (4).
f.
Tag two wire lugs (13) and remove screw (14) and two wire lugs from conduit box (3).
g.
Remove cable grip nut (15) from cable grip (16) and pull cable grip and three wires (13) and (9) out of conduit box
(3).
h.
Remove two screws (17), flat washers (18), and cable clamps (19) securing chemical feed metering pump cable
assembly to ROWPU deck.
3-211