TM 10-4610-239-24
TM 08580B-24/3
3-51.
REPAIR CHEMICAL FEED METERING PUMP.
This task covers:
a. Disassembly.
b. Cleaning.
c. Inspection.
d. Assembly.
INITIAL SETUP.
a.
Tools. Tool Kit (Appx B, Sect III, Item 10).
Soft-Bristled Brush (Appx B, Sect III, Item 2).
b.
Materials/Parts.
Dry-cleaning Solvent (Appx C, Sect II, Item 16).
Detergent (Appx C, Sect II, Item 3).
Antiseize Tape (Appx C, Sect II, Item 17).
Container (large enough for chemical feed pump oil drain)
c.
Equipment Condition.
Chemical feed metering pump electric motor removed
Chemical feed metering pump metering and drive assembly removed
d.
General Safety Requirements.
WARNING
Dry-cleaning solvent AA 711 TYPE I & II is highly toxic and can ignite
organic materials, nitrates, carbides, and chlorates. Wear eye, skin, and
respirator protection. Use in a well-ventilated area.
3-214