TM 10-4610-240-10
TM 08580C-10/1
T.O. 40W4-13-21
2-9. OPERATING PROCEDURES.
a. Apply Electrical Power.
(2) Push TEST LAMP switch to check all lights and adjust dimmer knobs.
NOTE
R.O. PUMP LOW PRESSURE lamp on ROWPU control box assembly comes on as soon as power is
applied to the ROWPU.
(3) Push EMERGENCY STOP button whenever the following conditions exist:
FIGURE 2-48. EMERGENCY STOP BUTTON
WARNING
Operating personnel could be injured
or the equipment could be damaged
if operation of the ROWPU is
allowed to continue.
(a) HIGH PRESSURE lamp associated with R.O.
PUMP comes on but R.O. Pump does not automatically
stop.
(b) LOW PRESSURE lamp associated with R.O.
PUMP comes on but R.O. Pump does not automatically
stop.
(c) Some other serious trouble (malfunction)
indicated by noise, vibration, large water leaks, etc.
FIGURE 2-49. HIGH/LOW PRESSURE LAMPS
2-56