TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-45. CONTROL BOX ASSEMBLY MAINTENANCE - continued.
RECEPTACLE CONNECTORS.
WARNING
High voltages in this equipment can cause serious injury or death. Be certain that
all power is removed before performing maintenance.
NOTE
All receptacle connectors in the control box and junction box assemblies are
removed the same. One receptacle connector is shown as typical.
a.
Remove cap (16) from receptacle connector (2).
NOTE
If working on junction box assembly, go to step d.
b.
To remove receptacle connector located in the control box assembly (10), remove 14 screws (13),
c.
Lower control box cover (14) and go to step e.
d.
To remove receptacle connector from the junction box assembly (7), turn 13 rotary
3-252