TM 10-4610-241-10
TO 40W4-13-41
3-8. SWITCH INDICATOR LAMP REPLACEMENT.
This task consists of:
a.
Removal
b.
Installation
INITIAL SET-UP:
Tools Required:
Equipment Condition:
Lamp extractor (from Storage Chest)
ROWPU shutdown (para 2-14)
Material/Parts:
Lamp (from Storage Chest)
NOTE
Replacement of R.O. PUMP HIGH PRESSURE switch indicator lamp is shown. Replacement of
other switch indicator lamps is similar.
a.
Removal. Refer to figure 3-9.
(1)
Remove lens cover (4) from lamp socket (2)
(2)
Using lamp extractor (5) from storage chest, remove lamp (3) from socket (2) on control box (1).
b.
Installation. Refer to figure 3-9.
(1)
Using lamp extractor (5), install lamp (3) in lamp socket (2) on control box (1).
(2)
Install lens cover (4) on lamp socket (2).
3-34