TM 10-4610-241-10
TO 40W4-13-41
3.9. CONTROL PANEL LAMP REPLACEMENT.
This task consists of:
a.
Removal
b.
Installation
INITIAL SET-UP:
Material/Parts:
Equipment Condition:
Lamp (from Storage Chest)
ROWPU shutdown (para 2-14)
a.
Removal. Refer to figure 3-10.
(1)
While depressing detent button (8) with thumb, pull quick release pin (9) from light bracket (1).
(2)
Pull out panel light bracket (1) from control panel (8).
(3)
Loosen screw (6) and remove guard (7) from fixture body (2).
(4)
Unscrew globe (5) from fixture body (2).
(5)
Unscrew lamp (4) from socket (3).
b.
Installation. Refer to figure 3-10.
(1)
Screw lamp (4) into socket (3).
(2)
Screw globe (5) onto fixture body (2).
(3)
Position guard (7) on fixture body (2) and tighten screw (6).
(4)
Push panel light bracket (1) into control panel (8).
(5)
While depressing detent button (8) with thumb, push quick release pin (9) through light bracket (1) and into
frame of control panel (8).
3-36