TM 10-4610-241-10
TO 40W4-13-41
Table 2-2. Operator Preventive Maintenance Checks and Services
Item
No.
24
25
26
27
28
Interval
After
After
After
After
After
Location
Item To Check/
Service
Waste Water
System (Vent
Vessels and Waste
Lines)
Control Panel
ROWPU
INTERIOR
Booster Pump
RO Pump
(Models WPES-10,
WPES-20 and
WPES-30 only)
Chemical Feed
Pump
Procedure
f. Inspect Tank in accordance with TM 5-
5430-225-12&P.
g. Inspect Nozzles for corrosion, cracks or
missing hardware
Inspect Hoses for tears, cuts, signs of dry
rot and missing gaskets.
a. Inspect Panel Light and Indicator Lights
for proper operation of iris and cracked or
broken bulbs and lenses.
b. Inspect TDS Monitor for cracked
housing, damaged cover or electric cables.
c. Inspect gages for cracked and broken
glass.
d. Inspect Vents, Valves and Drains for
corrosion and missing or damaged
hardware.
Inspect Booster Pump Motor for
discoloration and damaged or missing
hardware.
a. Inspect RO Pump Motor for
discoloration and damaged or missing
hardware.
b. Check that oil site gage is in red area of
site glass. Add oil as required.
c. Check Gearbox for signs of leakage.
d. Insect belt Guard for cracks, corrosion,
loose or missing hardware.
e. Inspect V-Belts for cuts, cracks, frayed
or worn belts.
a. Inspect Chemical Feed Pump Electric
Motor for discoloration and damaged or
missing hardware.
Not Fully Mission Capable
If:
In accordance with
TM5-5430-225-12&P
Tears, cuts, signs of dry rot or
missing gaskets
Valves damaged
Discoloration or damaged or
missing hardware
Discoloration or damaged or
missing hardware
Oil level too low
Class III leaks
Hardware missing
V-Belt cut, cracked, frayed or
worn
Discoloration or damaged or
missing hardware
2-34 Change 2