TM 10-4610-241-24
TO 40W4-13-42
3-39. MOTOR (CHEMICAL FEED PUMP) REPAIR - continued.
a.
Disassembly.
(1)
Scribe a line across junctions of end plates (7 and 16) and stator assembly (24) and remove four bolts (1),
flatwashers (2) and lockwashers (3).
(2)
Tap end plate (7) with soft-faced mallet to break bond with stator assembly (24).
CAUTION
Stator assembly wiring is connected to stationary switch which is attached to end plate.
To prevent damage to wiring, make sure stationary switch is disconnected before
removing end plate.
(3)
Carefully separate end plate (7) from stator assembly (24).
NOTE
Tagging wires, noting connection points will facilitate installation. Be sure to transfer
tags to replacement parts before discarding defective parts or turning them in to Supply.
(4)
(5)
(6)
(7)
Tag and disconnect wiring from stationary switch (5).
Remove two screws (4), stationary switch (5) and gasket (6) from end plate (7).
Remove load spring (8) and wavy washers (9) from end plate (7) or shaft of rotor (23).
Remove four screws (10) and capacitor cover (11) from stator assembly (24).
WARNING
To prevent possible electrical shock, capacitor should be discharged to ground before
disconnecting wires.
NOTE
Tagging wires, noting connection points will facilitate installation. Be sure to transfer
tags to replacement parts before discarding defective parts or turning them in to Supply.
(8)
Discharge capacitor and tag wiring, attached to capacitor. Disconnect wiring and remove capacitor ( 13)
from stator assembly.
(9)
(10)
(11)
Remove gaskets (12) from stator assembly (24).
Remove two screws (14) and washers (15), securing end plate (16) to retainer plate (20).
Tap end plate (16) with a soft-faced mallet to break bond with stator assembly (24) and remove plate.
Remove lip seal ( 17) from from end plate (16).
NOTE
Marking position of end plates on stator assembly will facilitate installation. Be sure to
transcribe markings to replacement parts before discarding defective parts or turning
them in to Supply.
3-218