TM 10-4610-241-24
TO 40W4-13-42
3-39. MOTOR (CHEMICAL FEED PUMP) REPAIR - continued.
CAUTION
Stator assembly wiring can be damaged by rotor or rotor shaft if it is not removed carefully.
(12)
Carefully pull rotor (23) out of stator assembly (24).
(13)
Remove retaining ring (18) from shaft of rotor (23).
(14)
Using arbor press, remove bearing (19) and retaining plate (20) from shaft of rotor (23).
(15)
Remove bearing (21), using arbor press, from shaft of rotor (23).
NOTE
Do not attempt to remove centrifugal switch cutout (22) from motor
shaft. This item cannot be replaced without damaging it and is not
available in Supply. If switch cutout is defective, replace entire motor.
(16)
A required, remove tape (25) from inside of capacitor cover (11).
3-219