ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0006 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
EQUIPMENT OFF-LOADING MARINE CORPS UNIT
WARNING
Three person lift. Three people are required to safely move the diesel pump skid.
Lift with your legs, not your back. Failure to observe this warning may result in
back injury.
Two person lift. Two people are required to safely move the distribution tank,
power cable, and BII box #5. Lift with your legs, not your back. Failure to observe
this warning may result in back injury.
7. Remove the diesel pump skid retaining rods and the pump skid.
8. Remove the 3000-gallon distribution tank.
9. With another person assisting, uncoil the power cable and route it out the end of the skid.
NOTE
The caustic cleaner liquid (sodium hydroxide) in the four bottles in BII Box #5
solidifies at temperatures of 53 degrees F and lower. The caustic must be stored
in a location warmer than 53 degrees F.
10. Remove BII Box #5.
WARNING
Chemical dust. If any chemical buckets or chemical packets are broken and
chemical dust is present, wear a dust mask, a protective face shield, and chemical
gloves when handling. Avoid inhaling chemical dust or fumes. Failure to observe
this warning may result in mild irritation of the nose, throat, eyes, and skin.
Liquid chemicals. If any liquid chemical containers are broken, wear a protective
face shield, chemical gloves, and a chemical apron when handling. Keep water
ready when handling. Avoid contact with the liquid. Failure to observe this
warning may result in chemical burns, or severe irritation of the nose, throat, eyes,
and skin.
11. Remove the chemical buckets and lids.
0006 00-5