ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0009 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
COLD WEATHER SET-UP OPERATION UNDER UNUSUAL CONDITIONS
TWPS WASTE OUTLET
A-09
6 X 50 RED-BANDED D-HOSE
4 X 5 RED-BANDED S-HOSE
Figure 21. Waste Outlet Connection.
MAKING POWER CABLE CONNECTIONS TO THE TWPS
1. Uncoil the electrical power cables for the P-2 and P-3 pumps. (The P-1 heater power cable is
uncoiled later, if the P-1 pump is used.)
WARNING
Electrical hazard. The TWPS operates on 416 Volts AC.
Making electrical
connections to the TWPS power distribution panel must be coordinated with the
procedures for establishing electrical power to the TWPS. Do NOT connect the
electrical power cables to the PDP at this time. Failure to observe this warning
may result in serious injury or death from electrocution.
2. For the MC-TWPS, insert all pump power cables that are to be used through the sleeve in the
winter cover at the PDP. Do NOT connect the power cables at this time.
3. For the A-TWPS, insert the power cables through the PDP access opening cover, insert the cover
into the access opening and pull it flush with the flat rack panel. Do NOT connect the power
cables at this time.
4. Allow the power cable ends inside the TWPS enclosure to warm for 20-30 minutes.
WARNING
Potential electrical hazard. Notify all crew members that you are ready to make
pump power connections to the PDP. Do NOT connect the power cables until all
personnel have been notified. Failure to observe this warning may result in injury
or death due to electrocution.
CAUTION
Connector damage or poor electrical connection. Use the fine brush from the tool
box to clean dust and sand out of connectors, terminals and dust caps before
making or capping a connection. Install the dust cap provided with connectors
and terminals whenever a connector is disconnected from its terminal. Failure to
observe this caution may result in connector damage or a poor electrical
connection.
0009 00-26