TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
FEED FLOW CONTROL PANEL
BOLT
FLAT WASHER
DISCONNECT TUBING HERE
TUBING ADAPTER
SOLENOID VALVE
XV-912
TUBING
ADAPTERS
IP TRANSDUCER FY-102
ELECTRICAL CONNECTION
SOLENOID VALVE XV-912
ELECTRICAL CONNECTION
Figure 5. Three Way Solenoid Valve XV-912.
2. Install the three way solenoid valve onto the feed flow control panel assembly as follows:
a. Apply antiseizing tape to the adapter threads.
b. Install the adapters into the new solenoid valve in the same position they were in the old
solenoid valve. Do not over-tighten.
c. Mount the 3-way solenoid valve onto the feed flow control panel assembly using the 2
lock nuts, 2 flat washers, and 2 screws.
d. Connect the 3 tubes that were disconnected from the old solenoid valve to the same
adapters in the new solenoid valve.
e. Reconnect the electrical connection to 3-Way Solenoid Valve XV-912
3. Check the feed flow control panel for proper operation and leaks.