ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0061 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
FEED FLOW CONTROL PANEL
DISCONNECT TUBING HERE
PRESSURE GAUGE PI-904
PANEL-MOUNT CONNECTOR
NUT
Figure 7. Pressure Gauge PI-904.
2. Install the new pressure gauge in the feed flow control panel assembly as follows:
a. Apply antiseizing tape to the new pressure gauge threads and the panel-mount connector
threads.
b. Install the panel mount connector onto the threads of the new pressure gauge.
c. Mount the new pressure gauge to the feed flow control panel assembly and secure it with
the nut.
d. Connect the tube that was disconnected from the pressure gauge to the connector on the
new pressure gauge.
3. Check the feed flow control panel for proper operation and leaks.
END OF WORK PACKAGE
0061 00-14