ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0061 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
FEED FLOW CONTROL PANEL
SET SCREW
SELECTOR VALVE V-914
FLAT NUT
SELECTOR KNOB
FERRULE
FERRULES
DISCONNECT TUBING HERE
Figure 6. Feed Control Selector Valve V-914.
2. Install the new Feed Control Selector Valve V-914 to the feed flow control panel assembly as
follows:
a. Loosen the ferrules on the new selector valve. Insert the tubes that were removed from
the old selector valve in the same ferrules in the new selector valve. Tighten the ferrules
to secure the tubes. Do not over-tighten.
b. Insert the selector valve through the panel and secure it to the panel with the flat nut.
c. Install the selector knob to the selector stem and secure it with the setscrew. Make sure
the knob is positioned in the manual feed position.
d. Connect the 3 tubes that were disconnected earlier to their appropriate locations.
3. Check the feed flow control panel for proper operation and leaks.
0061 00-12