ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0062 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
CONTROL INSTRUMENTS
Measure Screen:
-
o The measure screen can show seven different readout versions.
o The standard readout used for our configuration is shown in Figure 7.
o When the measure value is beyond the Transmitter's measuring range, series of
"+" or "-" screen symbols appear respectively indicating that the value is above or
below range.
A: 10.99mS, 25.3C
B: 5.000mS, 100 C
Figure 7. CIT-501 Conductivity RO Product Measure Screen Standard Configuration.
Configure the transmitter as follows:
a. Press the MENU key to display a "MAIN MENU" screen.
b. If the "MAIN MENU/CONFIGURE" screen is not showing, use the Up and Down
arrow keys to display it.
c. Press the ENTER key to display Configure/Set Output 1.
d. Press the Down arrow key until Configure/Language screen appears.
e. Press ENTER key to display a language like English.
f. Use the Up or Down key to select "English" as the language.
g. Press the ENTER key to enter the language selected.
NOTE
All listed sensor configuration instructions are for Sensor A. Configure Sensor B
in the same way and with same values as Sensor A, except as listed in
configuration step.
2. Select Measurement
a. With the Configure/Language screen displayed, press the Down key once to display
Configure/Sensor A (Press Down Key twice to display Configure/Sensor B).
0062 00-14