ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0063 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
POWER DISTRIBUTION SYSTEM
e. Using a flat-tip screwdriver, insert it into the DIN rail holding clip at the bottom right side of
the contactor. Gently pry down on the holding clip with the screwdriver to release the clip
from the DIN rail. Then lift up on the contactor and remove it from the DIN rail.
f. Remove the contactor assembly from the DIN rail.
g. Remove the surge suppressor clip from the contactor.
DIN RAIL
DIN RAIL HOLDING CLIP
OVERLOAD
AUTO/MAN
RESET DIAL
DIAL
AMP ADJUSTMENT DIAL
CONTACTOR/OVERLOAD RELAY/ SURGE SUPPRESSORS
SURGE SUPPRESSOR CLIP
THREE TERMINAL SCREWS
CONTACTOR
OVERLOAD RELAY
Figure 4. Contactor/Overload Relay/Surge Suppressor Assembly Replacement.
2. Install a new contactor/overload relay/surge suppressor assembly as follows:
a. Install the surge suppressor clip on the new contactor.
b. Position the new overload relay on the bottom of the new contactor.
c. Carefully insert the overload relay terminals into the contactor until locked in place.
d. Tighten the 3 terminal screws connecting the overload relay to the contactor.
0063 00-8