ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0063 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
POWER DISTRIBUTION SYSTEM
CIRCUIT BREAKER
SEAL
DIN RAIL
HOLDING CLIP
CIRCUIT BREAKERS WITH AUXILIARY SWITCH
SPRING CLAMP
AUXILIARY SWITCH
POWER DISTRIBUTION PANEL
Figure 1. Circuit Breaker with Auxiliary Switch Replacement.
2. Install a new circuit breaker and auxiliary switch as follows:
a. Set the new circuit breaker and auxiliary switch in the OFF position.
b. Break out the opening on the side of the new circuit breaker and remove the seal.
c. Position the auxiliary switch on the side of the circuit breaker.
d. Secure the auxiliary switch to the side of the circuit breaker using the two spring clamps.
e. Position the circuit breaker on the DIN Rail and carefully press the circuit breaker in
place.
f. Attach the wires to the screw connections in accordance to the wire tags.
g. Tighten the screw connections to secure the wires.
h. Remove the wire tags if necessary.
i. Reinstall the wire duct covers.
j. Close the power distribution panel.
0063 00-3