ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0066 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
GENERAL MAINTENANCE
Actuator (with Mechanical Position Indicator) Replacement
o Mounted on all butterfly valves listed above.
Actuator (with Pneumatic Positioner) Replacement
o Mounted on MF Filtrate Flow Control Butterfly Valve V-202
Grooved Coupling Replacement
Flexi Joint Expansion Joint Replacement
Pipe Coupling Replacement
Sanitary Clamp Replacement
Locking Arm Replacement
Actuator Repair
Collapsible Fabric Tank Repair
Antiseize Pipe Tape Installation
REPLACE
Clamped-On Hose Replacement:
Parts (TM 10-4610-309-24P):
Replacement hose
Replacement clamp
Equipment Condition:
TWPS in Standby Shutdown with or without draining down as required
Replace a hose that is clamped onto a fitting as follows (see Figure 1):
1. When replacing a clamped-on drain hose, make sure the TWPS is in Standby Shutdown without
2. For all clamped-on hoses other than a drain hose, make sure the TWPS is in Standby Shutdown
3. Turn the screw on the hose clamp to loosen the clamp and pull the clamp back down the hose
from the fitting.
4. Pull or cut the hose off the fitting.
5. Remove the hose from the fitting at the other end in the same manner.
NOTE
When measuring the length of a hose to be replaced, remember to include any
portions of the old hose that you cut off in the total length for the replacement
hose.
The black product tubing must be cut to a length so that, when installed, it does
not drop below the end connection on the 3-way valve.
6. Measure the hose length.
7. Cut new hose to length from bulk.
8. Obtain replacement clamps if the existing clamps are rusted, corroded, or need replacement for
any other reason.
9. Slide a clamp over one end of the replacement hose.
10. Push the hose all the way onto its fitting.
0066 00-2