ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0065 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
b. Remove the hardware that secures the bail bar to the flat rack as follows (see Figure 6):
1) Remove the eleven bolts, lockwashers, and flat washers that secure the bail bar
to the top horizontal beam of the flat rack.
2) Remove the four bolts, eight flat washers, four lock washers, and four nuts that
secure the bail bar to the diagonal beam of the flat rack.
3) Insert the flat end of the pinch bar between the large back nut and the flat rack
frame at the bottom of the flat rack.
4) Unscrew the bolt out of the nut using the bail bar socket wrench. Retain the bolt,
lock washer and nut.
5) Remove the back bolt, lock washer and nut at the other side of the bail bar in the
same manner.
BOLT, LOCK WASHER, FLAT WASHER
TOP FRAME OF FLAT RACK
BAIL BAR
LOCK WASHER
DIAGONAL FRAME OF FLAT RACK
FLAT WASHER
NUT
BOLT AND FLAT WASHER
PINCH BAR
BOLT, LOCK WASHER, NUT
BAIL BAR SOCKET WRENCH
Figure 6. Removing the Bolts from the Bail Bar.
0065 00-6