3) Carefully align and set an end cap onto the spring assemblies so that the cone
shaped projections of the end cap fit into the ends of the inner guides
4) Insert four end cap bolts with four flat washers through the holes in the end cap.
5) Push down on the end cap, compressing the springs enough to start threading
the bolts into the actuator body.
6) Tighten each bolt a little at a time until the end cap is fully tightened down onto
the actuator body.
7) Torque the bolts as follows:
a) 51.5 in.-lbs. for the 4-inch (smaller) actuators
b) 117.5 in.-lbs. for the 9-inch (larger) actuators
8) Repeat the previous 7 steps for the other end cap.
INNER GUIDE
END CAP
FLAT WASHER
END CAP BOLT
SPRING ASSEMBLY
PISTON HEAD CAVITY
ACTUATOR BODY
Figure 23. End Cap Assembly.
j.
Align the position indicator keys with the keyways on top of the pinion shaft and push the
position indictor fully onto the shaft.
k.
Make sure the air connection plate O-rings are in place.
l.
Position the plate on the actuator body with the silencer to the left and secure the plate
using the two cap head bolts and washers (see Figure 23).
0066 00-25