TM 10-4610-310-14
0002 00
ADDITIONAL EQUIPMENT continued
Cold Weather Kit
The cold weather kit is used when the ambient temperature is expected to be 32F (0C) or lower. The LWP is
set up inside a heated general-purpose medium tent to protect the equipment from the elements. The two 25-
foot raw water hoses from the water source and raw water pump are covered with electric thermal blankets and
routed to the settling tank inside the tent. The two 50-foot reject hoses are routed from the UF module and RO
element module are covered with electric thermal blankets and routed to the brine pit or downstream of the raw
water hose intake.
The cold weather kit contains one power distribution panel with five receptacles, 25-foot electrical cord, and a
power on/off switch (See Figure 25), 15 thermal hose blankets (three configurations) (see Figure 26.), one
thermal raw water service pump blanket, one carbon monoxide detector, five 15-foot extension cables, and one
high-pressure pump exhaust hose with adapter.
The power for the cold weather kit is supplied from a separate 3kW TQG set.
Figure 25. Power Distribution Panel.
Figure 26. Electric Thermal Blankets.