TM 10-4610-310-14
0004 00
KEY
CONTROL OR INDICATOR
FUNCTION
Temperature gauge -20 to 120F
9
Measures the temperature of feed to UF
water
10
Level switch LSL-1
Controls filtrate water flow to filtrate tank T2
11
Flow controller, 4 to 32 psi, 5 GPM, V41
Controls flow of filtrate water in filtrate to
tank piping
12
Vacuum release valve, 0.5-inch, V37
Relieves when a negative pressure is
detected in the filtrate tank
13
Flow control valve, 8 GPM, V51
Controls flow of water in the
filtrate/backwash piping
14
Relief valve, 5 to 15 psig, adjustable set
Relief pressure when set point is exceeded
point, V29
in filtrate tank vent piping
HIGH-PRESSURE PUMP MODULE
Controls and indicators on the high-pressure pump module are identified on Figure 9, Figure 10, and described
in Table .
1
3
10
2
8
Figure 9. High-Pressure Pump Module.