TM 10-4610-310-14
0009 00
STARTUP - CONTINUED
12. Flow is read at the top of the float on the flow meter on the high-pressure pump module. See Figure 30.
Figure 30. High-Pressure Pump Module Flow Meter.
WARNING
Never exceed 1200 psi of pressure. Injury or death of personnel may occur.
13. Once the proper flow to the RO module is achieved, adjust the reject control valve V11 on the RO
module for product water flow. See Figure 10.
NOTE
Raw water is treatable up to 60,000 ppm TDS. 125 GPH is produced from freshwater and 75
GPH from saltwater 20,001 to 45,000 ppm TDS. If the feed water TDS is higher than 45,000
14. Open or close the valve V11 slowly until the product water flow meter on the chemical module indicates
2.1 GPM for freshwater (less than 20, 000 ppm source water) or 1.25 GPM for seawater (at or above
20, 000 ppm source water). See Figure 31.
JUNCTION BOX
HYPOCHLORITE
INJECTION
PUMP
THERMOMETER
ANTISCALANT
PRODUCT WATER FLOW
INJECTION
METER
PUMP
TOTALIZER
COAGULANT
INJECTION PUMP
Figure 31. Chemical Injection/Cleaning Module.