TM 10-4610-310-14
0050 00
CLEANING - CONTINUED
3. Rinse floating strainer with clean water.
NOTE
Backwash the floating strainer by connecting it to the discharge fitting on the backwash pump and placing the
backwash pump switch to ON.
WIRE CLOTH
STRAINER
BODY WITH
CAP
PERFORATED
SHEET
STRAINER BODY
BUSHING
BASE BUSHING
NIPPLE
QUICK
ELBOW
DISCONNECT
Figure 3. Strainer Assembly (Exploded View).
ASSEMBLY
1. Slide wire cloth into strainer body.
2. Slide perforated sheet into strainer body.
3. Make sure all strainer holes are completely covered with the wire cloth.
4. Apply anti-seize tape to strainer body bushing threads. See Figure 3.
5. Thread the strainer body bushing into the strainer body. Hand-tighten only.
6. Connect male quick disconnect on inlet tank hose to female quick disconnect on elbow.
7. Place the strainer assembly into the settling tank. See Figure 1.
END OF WORK PACKAGE