TM 10-4610-310-14
UNIT MAINTENANCE
LIGHTWEIGHT WATER PURIFIER
TROUBLESHOOTING PROCEDURES
ULTRAFILTRATION MODULE
GENERAL
This work package lists the common malfunctions that you may find during the operation or maintenance of the
0.75-inch pilot-operated solenoid valve V2C on the Ultrafiltration (UF) module used on the Lightweight Water
Purifier (LWP). You should perform the tests/inspections and corrective action in the order listed.
This manual cannot list all malfunctions that may occur, nor all tests or inspections and corrective actions. If a
malfunction is not listed or is not corrected by listed corrective actions, notify your supervisor.
WARNING
When checking for voltage on an energized component, extreme care must be taken. Only qualified and
authorized electrician should maintain, troubleshoot, and operate energized equipment. Injury or death to
personnel may result.
MALFUNCTION
TEST/INSPECTION
CORRECTIVE ACTION
With the power on, check
If voltage is present preceed to
voltage across wire 34 and
the next step. If not skip to
3 for 120 VAC at the UF
malfunction 2.
junction box terminal block.
Remove connector at valve.
Replace connector or wiring to
connector. If corrected voltage
34 , 3 and ground to terminal
should be present across wire 34
block TB1 in UF module
and 3 at the valve now.
junction box.
1. Valve will not open
Check and make sure that
the coil is mounted properly
Tighten coil mounting nut.
on top of the valve.
should be between 108
Replace valve if still inoperable.
Test for opeartion.
If voltage is present at the
If the voltage is not avilable
connection on the control
at the UF junction box, test
module side, inspect the UF
for voltage across pin G and
J (120 VAC) on the
wire 34 to pin G and ,also, wire 3
connection (J6) at the
to pin J. Replace cable if
2. Valve will not open
necessary. Proceed if continuity
control module.
voltage is not available.
is present.
Inside the control panel,
Tighten loose connection.
check connections of wire
34 from output 5 of PLC
Replace or repair broken wires
and connections.
output card 1(OC1) to pin G.
0056 00-1