TM 10-4610-310-14
DIRECT SUPPORT/GENERAL SUPPORT MAINTENANCE
LIGHTWEIGHT WATER PURIFIER
ULTRAFILTRATION MODULE
SOLENOID VALVE
REPAIR
INITIAL SETUP
Tools
Material/Parts
Shop equipment, automotive, common 1 and 2
Equipment Condition Required
Coil assembly, (PN 6470W-ASM-120/60)
Discontinue fluid and electrical service
GENERAL
This work package contains information and instructions for repair of solenoid valve on the Ultrafiltration (UF)
module used in the Lightweight Water Purifier (LWP).
NOTE
See WP 0088 00 for instructions on replacing the top works of the solenoid valve.
DISASSEMBLY
1. Remove the cap nut (1) and O-ring (2) and slide the coil (3) off from the valve (7). See Figure 1.
2. Remove the screw (6) from the electrical connector (5)
3. Disconnect the wires inside, if needed. Ensure to note the location of the wires on the connector for assembly.
The connections are marked with the numbers 1,2, and ground symbol.
4. Disconnect electrical connector (5) from the coil (3).
GROUND
PRONG
Figure 1. Solenoid Valve (Exploded View).