TM 10-4610-310-14
UNIT MAINTENANCE
LIGHTWEIGHT WATER PURIFIER
ULTRAFILTRATION MODULE
SOLENOID VALVE REPAIR
INITIAL SETUP
Tools
Material/Parts
Tool Kit, LWP (PN 3600486000)
Valve, solenoid, PN 2606639001(with hole)
Equipment Condition Required
Valve, solenoid, PN 2606639000 (without hole)
Discontinue fluid and electrical service
GENERAL
This work package contains information and instructions for removal and installation of the 0.75-inch (19.05-mm)
pilot-operated solenoid valves on the Ultrafiltration (UF) module used in the Lightweight Water Purifier (LWP).
There are seven valves in the UF module; three valves with a 0.052-inch hole drilled inside the housing are at the
top in the UF reject piping, one valve in the middle in the tank inlet piping, and three valves at the bottom in the
fast flush piping.
REMOVAL
SOLENOID VALVE
(V3C) WITH HOLE
SOLENOID VALVE
(V3B) WITH HOLE
SOLENOID VALVE
(V3A) WITH HOLE
SOLENOID VALVE
(V7) WITHOUT HOLE
SOLENOID
VALVES (V2C)
WITHOUT HOLE
SOLENOID
VALVES (V2B)
SOLENOID
WITHOUT HOLE
VALVES (V2A)
WITHOUT HOLE
Figure 1. Ultrafiltration Module.