TM 5-3800-205-23-3
HYDRAULIC HOSES MAINTENANCE (DRAFT ARM-TO-WATER TANK)
THIS WORK PACKAGE COVERS
Removal, Disassembly, Assembly, Installation
INITIAL SETUP
Maintenance Level
References
Unit
TM 5-3800-205-23-1
Tools and Special Tools
Equipment Condition
Machine parked on hard, level surface (TM 5-3800-
Shop equipment, common no. 1 (Item 24, WP 0045
205-10-2)
Tank lowered to ground (TM 5-3800-205-10-2)
Materials/Parts
Parking brake engaged (TM 5-3800-205-10-2)
Wheels chocked (TM 5-3800-205-10-2)
Battery disconnect switch in OFF position (TM 5-
Seal, O-ring (2)
3800-205-10-2)
WARNING
Do NOT disconnect or remove any hydraulic system line or fitting unless engine is shut down and
hydraulic system pressure has been relieved. Tighten all connections before applying pressure. Escap-
ing hydraulic fluid under pressure can penetrate the skin, causing serious injury.
At operating temperature hydraulic oil is hot. Allow hydraulic oil to cool before disconnecting any
hydraulics. Failure to do so could result in injury.
Hydraulic fluid is very slippery. Immediately wipe up any spills. Failure to follow this warning may
result in injury to personnel.
CAUTION
Wipe area clean around all hydraulic connections prior to disconnecting. Cap or plug all openings after dis-
connecting. Contamination of hydraulic system could result in equipment failure.
NOTE