TM 5-3800-205-23-3
HYDRAULIC HOSES MAINTENANCE (DRAFT ARM-TO-WATER TANK) - CONTINUED
0024 00
ASSEMBLY
CAUTION
Ensure all parts are free of dust or dirt to ensure no contamination to hydraulic system.
NOTE
Lubricate new O-rings with oil prior to installation.
1.
Install new O-ring (12) on adapter plate (13).
2.
Install adapter plate (13) to mount (11) with four socket head screws (8).
3.
Install elbow fitting (9) to adapter plate (13).
4.
Install adapter (10) and coupling (3) to elbow fitting (9).
5.
Install new O-ring (7) and connect hydraulic hose connector (6) to coupler (2).
INSTALLATION
NOTE
All quick disconnect connections are made the same way. Be sure to turn quick disconnect collar a half turn
after connecting to lock connection.
1.
Hydraulic hose (1) is installed by connecting each end at quick disconnects.
1
QUICK
DISCONNECTS
QUICK
DISCONNECTS
2.
Check hydraulic fluid level in reservoir (Refer to Unit PMCS in TM 5-3800-205-23-1).
3.
Operate hydraulics (TM 5-3800-205-10-2) and check for leaks.
END OF WORK PACKAGE
0024 00-5