TM 5-3800-205-23-3
CONTROL PANEL AND AIR HOSES MAINTENANCE - CONTINUED
0029 00
CONTROL PANEL ASSEMBLY REMOVAL
1.
Disconnect electrical cable (1) from receptacle connector (2).
3
2
4
1
5
6
8
7
2.
Disconnect air hose (5) from air supply (6).
3.
Remove pin (8) from mount boss (7) and control panel (4).
NOTE
Tag air hoses to ensure correct installation.
To disconnect air hoses from push-in fittings, depress collar against body of fitting and remove air hose.
4.
Tag and disconnect seven air hoses (3) from push-in fittings at control panel (4).
CONTROL PANEL ASSEMBLY INSTALLATION
NOTE
To connect air hoses to push-in fittings, insert hose into fitting until it bottoms. Push twice to ensure air hose
is inserted past fitting collet and O-ring. Pull on hose to confirm connection is secure.
1.
Connect seven air hoses (3) to push-in fittings at control panel (4). Remove tags.
2.
Position control panel (4) in mount boss (8) and install pin (7).
3.
Connect air hose (5) to air supply (6).
4.
Connect electrical cable (1) to receptacle connector (2).
0029 00-2