TM 5-3800-205-23-3
CONTROL PANEL AND AIR HOSES MAINTENANCE - CONTINUED
0029 00
WORK LIGHT SWITCH REMOVAL
1.
Loosen but do not remove six screws (9) and panel locks (10).
2.
Open panel (4).
3.
Tag wires (26).
4.
Disconnect wires (26) from switch terminals (27).
5.
Remove nut (23), ON/OFF face plate (24), and switch (25) from panel (4).
10
9
4
24
23
25
26
27
WORK LIGHT SWITCH INSTALLATION
1.
Position switch (25) on panel (4).
NOTE
ON/OFF face plate is installed with word ON facing up.
2.
Install ON/OFF face plate (24) and nut (23) on switch (25).
3.
Connect wires (26) to switch terminals (27).
4.
Remove tags from wires (26).
5.
Close panel (4).
6.
Tighten six screws (9) and panel locks (10).
0029 00-6