TM 5-3800-205-23-3
WATER HOSE ASSEMBLIES, INLET/OUTLET PIPES, AND
0035 00
UPPER PIPE REMOVAL
1.
2.
3.
Remove pressure gravity and tank fill sparger valve assemblies (WP 0027 00).
4.
Remove lower pipe (Refer to Lower Pipe Removal).
5.
Remove hose reel hose assembly from upper pipe (25).
6.
Remove two nuts (20), bolts (21), coupling (22), and seal (23) from upper pipe (25).
7.
With assistance, remove seal (23) and upper pipe (25) from water pump housing (24).
8.
Inspect seal (23) for dry rot, cracks or tears. If damaged, replace seal.
20,21
22,23 (HIDDEN)
25
24
UPPER PIPE INSTALLATION
1.
With assistance position seal (23) and upper pipe (25) on water pump housing (24).
2.
Install coupling (22) and seal (23) on upper pipe (25) with two bolts (21) and nuts (20).
3.
Instal hose reel hose assembly on upper pipe (25).
4.
Install lower pipe (Refer to Lower Pipe Installation).
5.
Install pressure gravity and tank fill sparger valve assemblies (WP 0027 00).
6.
7.
0035 00-6