TM 5-4610-218-34
Section II. DIATOMITE DILUTION TANK ASSEMBLY
WARNING
diatomite dilution tank provides storage for di-
atomite slurry to supply the suction line of the
filter pump.
Dry cleaning solvent, P-D-680,
used to clean parts, is potentially
b. Removal. Remove the diatomite dilution
dangerous. Avoid repeated and
prolonged breathing of the vapors
and skin contact with the liquid.
c. Clean, Inspect and Replace.
Do not use near open flame or ex-
(1) Clean the diatomite dilution tank with
cessive heat. Use in a well-venti-
dry cleaning solvent P-D-680.
lated area. The flash-point of P-D-
680 is 100-138F (38-59C).
(2) Inspect the tank for cracks, breaks, and
other damage.
5-2. Diatomite Dilution Tank Assembly.
(3) Replace a damaged or defective dilution
tank.
a. General. The diatomite dilution tank is
made of aluminum and is welded watertight. It
d. Installation. Install the diatomite dilution
is mounted to brackets on the slurry feeder. The
Figure 5-12. Chemical Slurry Feeder Diatomite Dilution Tank, Removal and Installation