TM 55-1930-209-14&P-19
Table 4-2. Preventive Maintenance Checks and Services for ROWPU System (Continued)
B -
Before
D -
Daily
Q - Quarterly
D -
During
W -
Weekly
S - Semiannually
A -
After
M -
Monthly
A - Annually
INTERVAL
ITEM
PROCEDURES
EQUIPMENT
ITEM
TO BE
CHECK FOR AND HAVE
IS NOT READY/
NO.
INSPECTED
REPAIRED OR ADJUSTED
AVAILABLE IF
B D A D W M Q S A
AS NECESSARY
12) Flush chlorination unit with seawater
before returning to normal operation
as follows:
(a) Turn valve CU3 to position B,
WATER, to allow seawater to
flush out acid.
(b) Turn valve CU5 to position A,
DRAIN, to allow flushing seawa-
ter to drain to sump tank.
(c) Turn function switch to FLUSH.
(d) Flush to remove acid for 5 min-
utes. Turn function switch on
control cabinet to OFF/RESET.
(e) Return system to normal opera-
tion.
8
Brine Feed Pump
Check that oil level in chlorination unit brine
feed pump is above indicated mark in air
bleeder filler reservoir. Add oil if necessary.
9
Metering Pump
Check sight on metering pump to ensure oil
level is at mark. Add oil as necessary.
10
Metering Pump
Monitor metering pump control unit to
Control Unit
assure chlorine status on LED display.
11
Chlorination Unit
a. Monitor ammeter to assure reading is
Control Cabinet
between 950-1000A (0.95-1.OkA).
b. Monitor voltmeter to assure reading is
between 6.0-6.5 Vdc.
12
Equipment
a. Monitor CHLORINE STATUS display
Monitoring
page for chlorine content and pump
System
position.
b. Monitor SYSTEM STATUS display page
to assure:
1) CHLORINE OPERATING OFF is
normal.
4-11