TM 55-1930-209-14&P-19
Table 5-2. Preventive Maintenance Checks and Services for Drinking Water System
B -
Before
D -
Daily
Q - Quarterly
D -
During
W -
Weekly
S - Semiannually
A -
After
M -
Monthly
A - Annually
INTERVAL
ITEM
PROCEDURES
EQUIPMENT
ITEM
TO BE
CHECK FOR AND HAVE
IS NOT READY/
NO.
INSPECTED
REPAIRED OR ADJUSTED
AVAILABLE IF
B D A D W M Q S A
AS NECESSARY
DRINKING
WATER SYSTEM
WARNING
Be sure electrical power is OFF before per-
forming maintenance on electrical systems.
Redtag appropriate switches and circuit
breakers with: "WARNING - DO NOT ACTI-
VATE - REPAIRS BEING MADE." Observe all
safety precautions listed in the beginning of
this manual.
1
All Components
a. Wipe components clean, especially
gauges and control panels.
b. Check for leaks, paying special attention
Class Ill leaks.
to joints, valves, fittings, and piping.
Report leaks to shift leader or bargemas-
ter.
c. Check for loose or missing securements
or fasteners. Tighten or replace as neces-
sary.
d. Check for damage, especially to pres-
Pressure gauges
sure gauges, filters, and control panels.
damaged.
Notify shift leader or bargemaster so
repairs can be made.
e. Remove rust and corrosion.
Touch or
paint in accordance with TB 43-0144 as
necessary. Do not paint threads or
labels.
2
Wiring
a. Check wiring for loose or missing con-
Cables frayed.
nections and frayed cables. Secure,
tighten as necessary.
b. Visually check wiring for loose connec-
Sparks are seen.
tions. If sparks are seen, report to shift
leader or bargemaster. Shut power off.
5-4