Table 6-2. Preventive Maintenance Checks and Services for Shore Discharge System (Continued)
B -
Before
D -
Daily
Q - Quarterly
D -
During
W -
Weekly
S - Semiannually
A -
After
M -
Monthly
A - Annually
INTERVAL
ITEM
PROCEDURES
EQUIPMENT
ITEM
TO BE
CHECK FOR AND HAVE
IS NOT READY/
NO.
INSPECTED
REPAIRED OR ADJUSTED
AVAILABLE IF
B D A D W M Q S A
AS NECESSARY
3) When reservoir is completely drained,
replace plug. Wipe plug and area
around plug clean.
4) Remove and clean suction strainer.
5) Remove filler/breather cap.
6) Clean filter if necessary.
7) Fill reservoir with Gulf Harmony 46
AW or military equivalent until oil level
sight gauge indicates 100 percent full.
8) Replace cap.
9) Wipe clean reservoir and immediate
area.
4
Hydraulic
Check that charge pressure gauge on
Power Unit
hydraulic power unit reads no less than
Charge Pressure
250 psi. Minimum pressure needed for
Gauge
proper stroke control and makeup flow for
winch circuit.
5
Hydraulic.
Check hydraulic fluid level is 80 percent
Power Unit
or more full. Add fluid if necessary as
Level Gauge
follows:
WARNING
Wear safety glasses when adding
hydraulic fluid. In case of eye contact,
wash with lots of water. In case of skin
contact, wipe and then wash with soap
and water.
1) Remove filler/breather cap.
2) Clean filter.
3) Add Gulf Harmony 46AW or military
equivalent hydraulic fluid until level
gauge indicates 100 percent full.
4) Replace cap.
5) Wipe reservoir and immediate area
clean.
6-4