TM 55-1930-209-14&P-19
Table 6-2. Preventive Maintenance Checks and Services for Shore Discharge System (Continued)
B -
Before
D -
Daily
Q - Quarterly
D -
During
W -
Weekly
S - Semiannually
A -
After
M -
Monthly
A - Annually
INTERVAL
ITEM
PROCEDURES
EQUIPMENT
ITEM
TO BE
CHECK FOR AND HAVE
IS NOT READY/
NO.
INSPECTED
REPAIRED OR ADJUSTED
AVAILABLE IF
B D A D W M Q S A
AS NECESSARY
7
Hydraulic
a.
With hose reel winch control lever in
Power Unit
NEUTRAL position on Barge 1 or in OFF
Piston Pump
position on barges 2 and 3, check that
piston pump low (return) and high (sup-
ply) pressure gauge readings are the
same.
b.
If the 2 readings differ, zero bias by
adjusting zero adjustment screen
(socket-headscrew) on end of piston
pump.
8
Hydraulic
a.
Check supply pressure gauge. If neces-
Pressure gauge
Power Supply and
sary replace filter element as follows:
cracked or bro-
Return Filters
ken.
1) Unscrew old filter.
2) Coat gasket on new filter with light
coat of oil.
3) Screw on new filter.
4) When operating after replacement,
check for leaks and make sure indica-
tor is operating normally.
b.
Check return pressure gauge. If neces-
Pressure gauge
sary, replace filter element as follows:
cracked or bro-
ken.
1) Turn bypass valve to bypass filter.
2) Unscrew old filter.
3) Coat gasket on new filter with light
coat of oil.
4) Screw on new filter.
5) Turn bypass valve to allow flow
through filter.
6) When operating after replacement,
check for leaks and make sure indica-
tor is operating normally.
6-6